No Break Eaton 9355 15 Kvas Doble Conversión 15,000VA 13,500W Entrada 220V Salida 220V Requiere Servicio De Arranque Por Parte De La Marca
$215,491.00$239,435.00 (-10%)
SKU: KA1511200000010
Garantía:
Promoción Válida Hasta: Sobre Pedido, Consultar Tiempo de Entrega.
NOTA: Puede recoger en almacén en la compra mínima de 1 equipo, pregunte por las condiciones.
Llame Ahora al 55 8190 3433 y pregúntenos todas sus dudas…
No Break Eaton 9355 15 Kvas Doble Conversión 15,000VA 13,500W Entrada 220V Salida 220V Requiere Servicio De Arranque Por Parte De La Marca – Solicitar Cotización.
Información Técnica:
No Break Eaton 9355 15 Kvas Doble Conversión
Modelo 9355
Capacidad 15 Kvas
Power Rating 15 Kvas/13.5Kw
Volt In 220
Volt Out 220/127
Conexión 4W+G
Dimensiones: 32.2 X 12.0 X 33.7
Peso: 373 Lb
Technical Specifications for 10 and 15 kVA Power
Ratings (kVA/Watts) 10 kVA/9 kW and 15 kVA/13.5 kW at 0.9 power factor
Topology Double conversion
Electrical input
Nominal input voltage 208V/120V or 220V/127V three-phase 400V models also available.
Input voltage range -15%, +10% from nominal at 100% load without depleting battery
Operating frequency 50/60 Hz (45 to 65 Hz)
1.- Input power factor >0.99 typical, >0.96 frequency converter
2.- Input current distortion 5% THD
Electrical output
Nominal output voltage 208/120, 220/127 Vac
Output voltage regulation ±1% static; ±5% dynamic at 100% resistive
load change, <1 ms response time
Efficiency 91%, typical
Heat dissipation (BTU/hr) 10 kVA models:
3,798 @ 208V and 220V input
6,294 @ 480V and 600V (with input
isolation transformer)
15 kVA models:
5,122 @ 208V and 220V input
8,134 @ 480V and 600V (with input
isolation transformer)
Battery
1.- Battery type 9 Ah, sealed, lead-acid, maintenance-free
2.- Battery runtime See battery backup time chart
3.- Battery replacement Field-replaceable
Charger Default is 3.4A per battery string. Charger current is configurable from 0.5A to 25A per string with an overall maximum of 34A (limited by input current).
Start-on-battery Allows start of UPS without utility input
General
Diagnostics Full system self-test at startup UPS bypass Automatic on overload or UPS failure Parallel for redundancy Yes, using Powerware Hot Sync technology
and capacity.
Dimensions and weights See model selection table Overload (normal operation) 150% for 5 sec / 125% for 1 min (online), 110% for 10 min
Communications
LCD display Graphical LCD with blue backlight
LEDs (4) LEDs for notice and alarm Audible alarms Yes
Communication ports (1) RS-232, (1) relay contact, (1) REPO, (2) environmental input
Slots (2) X-Slot communication bays
Power management software Bundled Software Suite CD
Environmental
Operating temperature 50–104ºF (10–40ºC), 45ºC with 7.5% derating;
Optimal battery performance: 77ºF (25ºC)
Storage temperature 32–77ºF (0–25ºC); Recommended battery storage:
59–77ºF (15–25ºC)
Relative humidity 0–95%, non-condensing
Audible noise < 56 dBA at 1 meter (noiseless room) typical
Altitude 9,843 ft. (3000m) without derating
Certifications
Safety certifications UL1778 5th Edition, CSA C22.2 No. 107.3-14,
NOM-NYCE
EMC compliance 47 CFR Part 15/ICES-003 Class A
Quality ISO 9001:2015, ISO 14001:2004
Surge ANSI C62.41 Category B3, IEC 61000-4-5
Markings cULus, NOM-NYCE
**Es Obligatorio Cotizar Servicio De Arranque Y Viáticos, De Lo Contrario Pierde Garantía En Automático
Product Brochure & Technical Specifications
Especificaciones KA1511200000010
Información Comercial:
El No Break 9355 Ups Proporciona Energía De Respaldo De Doble Conversión Premium Y Tiempos De Ejecución De Batería Modificables Para It E Infraestructura De Ingeniería Eléctrica Otros Sistemas Críticos En Aplicaciones Corporativas, De Atención Médica, Bancarias, E Industriales.
Compactar El Máximo Tiempo De Ejecución De Batería En Muy Poco Espacio Convierte El No Break Eaton 935 En Una Solución De Protección De Energía Trifásica Realmente Completa.
Información adicional
Capacidad Va | 15000 Va |
---|---|
Capacidad Watts | 13500 Watts |
Reviews